24 research outputs found

    Accuracy of the Multisensory Wristwatch Polar Vantage's Estimation of Energy Expenditure in Various Activities: Instrument Validation Study.

    Get PDF
    Sport watches and fitness trackers provide a feasible way of obtaining energy expenditure (EE) estimations in daily life as well as during exercise. However, today's popular wrist-worn technologies show only poor-to-moderate EE accuracy. Recently, the invention of optical heart rate measurement and the further development of accelerometers in wrist units have opened up the possibility of measuring EE. This study aimed to validate the new multisensory wristwatch Polar Vantage and its EE estimation in healthy individuals during low-to-high-intensity activities against indirect calorimetry. Overall, 30 volunteers (15 females; mean age 29.5 [SD 5.1] years; mean height 1.7 [SD 0.8] m; mean weight 67.5 [SD 8.7] kg; mean maximal oxygen uptake 53.4 [SD 6.8] mL/min·kg) performed 7 activities-ranging in intensity from sitting to playing floorball-in a semistructured indoor environment for 10 min each, with 2-min breaks in between. These activities were performed while wearing the Polar Vantage M wristwatch and the MetaMax 3B spirometer. After EE estimation, a mean (SD) of 69.1 (42.7) kcal and 71.4 (37.8) kcal per 10-min activity were reported for the MetaMax 3B and the Polar Vantage, respectively, with a strong correlation of r=0.892 (P<.001). The systematic bias was 2.3 kcal (3.3%), with 37.8 kcal limits of agreement. The lowest mean absolute percentage errors were reported during the sitting and reading activities (9.1%), and the highest error rates during household chores (31.4%). On average, 59.5% of the mean EE values obtained by the Polar Vantage were within ±20% of accuracy when compared with the MetaMax 3B. The activity intensity quantified by perceived exertion (odds ratio [OR] 2.028; P<.001) and wrist circumference (OR -1.533; P=.03) predicted 29% of the error rates within the Polar Vantage. The Polar Vantage has a statistically moderate-to-good accuracy in EE estimation that is activity dependent. During sitting and reading activities, the EE estimation is very good, whereas during nonsteady activities that require wrist and arm movement, the EE accuracy is only moderate. However, compared with other available wrist-worn EE monitors, the Polar Vantage can be recommended, as it performs among the best

    Accuracy of Distance Recordings in Eight Positioning-Enabled Sport Watches: Instrument Validation Study

    Get PDF
    Elite athletes and recreational runners rely on the accuracy of global navigation satellite system (GNSS)-enabled sport watches to monitor and regulate training activities. However, there is a lack of scientific evidence regarding the accuracy of such sport watches.; The aim was to investigate the accuracy of the recorded distances obtained by eight commercially available sport watches by Apple, Coros, Garmin, Polar, and Suunto when assessed in different areas and at different speeds. Furthermore, potential parameters that affect the measurement quality were evaluated.; Altogether, 3 × 12 measurements in urban, forest, and track and field areas were obtained while walking, running, and cycling under various outdoor conditions.; The selected reference distances ranged from 404.0 m to 4296.9 m. For all the measurement areas combined, the recorded systematic errors (±limits of agreements) ranged between 3.7 (±195.6) m and -101.0 (±231.3) m, and the mean absolute percentage errors ranged from 3.2% to 6.1%. Only the GNSS receivers from Polar showed overall error

    Eyeblink Detection in the Field: A Proof of Concept Study of Two Mobile Optical Eye-Trackers.

    Get PDF
    High physical and cognitive strain, high pressure, and sleep deficit are part of daily life for military professionals and civilians working in physiologically demanding environments. As a result, cognitive and physical capacities decline and the risk of illness, injury, or accidents increases. Such unfortunate outcomes could be prevented by tracking real-time physiological information, revealing individuals' objective fatigue levels. Oculometrics, and especially eyeblinks, have been shown to be promising biomarkers that reflect fatigue development. Head-mounted optical eye-trackers are a common method to monitor these oculometrics. However, studies measuring eyeblink detection in real-life settings have been lacking in the literature. Therefore, this study aims to validate two current mobile optical eye-trackers in an unrestrained military training environment.; Three male participants (age 20.0 ± 1.0) of the Swiss Armed Forces participated in this study by wearing three optical eye-trackers, two VPS16s (Viewpointsystem GmbH, Vienna, Austria) and one Pupil Core (Pupil Labs GmbH, Berlin, Germany), during four military training events: Healthcare education, orienteering, shooting, and military marching. Software outputs were analyzed against a visual inspection (VI) of the video recordings of participants' eyes via the respective software. Absolute and relative blink numbers were provided. Each blink detected by the software was classified as a "true blink" (TB) when it occurred in the software output and the VI at the same time, as a "false blink" (FB) when it occurred in the software but not in the VI, and as a "missed blink" (MB) when the software failed to detect a blink that occurred in the VI. The FBs were further examined for causes of the incorrect recordings, and they were divided into four categories: "sunlight," "movements," "lost pupil," and "double-counted". Blink frequency (i.e., blinks per minute) was also analyzed.; Overall, 49.3% and 72.5% of registered eyeblinks were classified as TBs for the VPS16 and Pupil Core, respectively. The VPS16 recorded 50.7% of FBs and accounted for 8.5% of MBs, while the Pupil Core recorded 27.5% of FBs and accounted for 55.5% of MBs. The majority of FBs-45.5% and 73.9% for the VPS16 and Pupil Core, respectively-were erroneously recorded due to participants' eye movements while looking up, down, or to one side. For blink frequency analysis, systematic biases (±limits of agreement) stood at 23.3 (±43.5) and -4.87 (±14.1) blinks per minute for the VPS16 and Pupil Core, respectively. Significant differences in systematic bias between devices and the respective VIs were found for nearly all activities (P < .05).; An objective physiological monitoring of fatigue is necessary for soldiers as well as civil professionals who are exposed to higher risks when their cognitive or physical capacities weaken. However, optical eye-trackers' accuracy has not been specified under field conditions-especially not in monitoring fatigue. The significant overestimation and underestimation of the VPS16 and Pupil Core, respectively, demonstrate the general difficulty of blink detection in the field

    Detecting Soldiers' Fatigue Using Eye-Tracking Glasses: Practical Field Applications and Research Opportunities.

    Get PDF
    Objectively determining soldiers' fatigue levels could help prevent injuries or accidents resulting from inattention or decreased alertness. Eye-tracking technologies, such as optical eye tracking (OET) and electrooculography (EOG), are often used to monitor fatigue. Eyeblinks-especially blink frequency and blink duration-are known as easily observable and valid biomarkers of fatigue. Currently, various eye trackers (i.e., eye-tracking glasses) are available on the market using either OET or EOG technologies. These wearable eye trackers offer several advantages, including unobtrusive functionality, practicality, and low costs. However, several challenges and limitations must be considered when implementing these technologies in the field to monitor fatigue levels. This review investigates the feasibility of eye tracking in the field focusing on the practical applications in military operational environments.; This paper summarizes the existing literature about eyeblink dynamics and available wearable eye-tracking technologies, exposing challenges and limitations, as well as discussing practical recommendations on how to improve the feasibility of eye tracking in the field.; So far, no eye-tracking glasses can be recommended for use in a demanding work environment. First, eyeblink dynamics are influenced by multiple factors; therefore, environments, situations, and individual behavior must be taken into account. Second, the glasses' placement, sunlight, facial or body movements, vibrations, and sweat can drastically decrease measurement accuracy. The placement of the eye cameras for the OET and the placement of the electrodes for the EOG must be chosen consciously, the sampling rate must be minimal 200 Hz, and software and hardware must be robust to resist any factors influencing eye tracking.; Monitoring physiological and psychological readiness of soldiers, as well as other civil professionals that face higher risks when their attention is impaired or reduced, is necessary. However, improvements to eye-tracking devices' hardware, calibration method, sampling rate, and algorithm are needed in order to accurately monitor fatigue levels in the field

    Relationship of body condition and milk parameters during lactation in Simmental cows in Bavaria, Germany

    Get PDF
    In dairy cows the body condition forms a reflection of the energy reserves of the organism. Health, welfare and productivity of dairy cows are strongly associated with changes in body condition. As lactation puts substantial demands on the metabolism of dairy cows, farm management aims at avoiding either a deficient body condition or a substantial loss of body condition within a short period of time. A body condition higher or lower than recommended (over- and underconditioning in the following) compromises dairy cow productivity. While the body condition of Holstein Friesian cows has been thoroughly explored, few is known about the consequences of deviations from a target body condition for health and productivity of cows from other breeds. This study explores the percentage of over- and underconditioned cows at different days post partum [dpp] and their association with production parameters i.e., milk yield, milk fat and milk protein content of Simmental cows on Bavarian farms, categorized by parity (primi- or multiparous). Our study displays that in Simmental cows, overconditioning is more prevalent than underconditioning. While the middle of lactation (dpp = 100–199) resulted in higher percentage of overconditioning, the dry period (dpp = 299) indicated a higher percentage of underconditioned cows. The dry period and the middle of lactation are therefore the most challenging lactation stages for Simmental cows. We found milk protein content to have the strongest association with over- and underconditioning in Simmental cows. The probability of overconditioning was higher with higher milk protein content for every lactation stage and the probability of underconditioning was lower with higher milk protein content in every lactation stage. This study provides a theoretical basis for potential improvements in stockbreeding, which, if implemented, could improve not only the milk yield of Simmental dairy cows, but also their health and welfare

    Bayerisches Erfahrungswissen zum Einsatz von Arzneipflanzen bei Nutztieren – eine Basis für die traditionelle europäische Veterinärphytotherapie?

    Get PDF
    Das seit Generationen schriftlich und mĂĽndlich ĂĽberlieferte Erfahrungswissen von Tierhalter*innen stellt eine wichtige Grundlage fĂĽr den Einsatz und die zukĂĽnftige Entwicklung pflanzlicher Tierarzneimittel dar. Im Rahmen dieser Studie wurde dieses Wissen fĂĽr Bayern zusammengetragen

    A cluster randomized controlled platform trial comparing group MEmory specificity training (MEST) to group psychoeducation and supportive counselling (PSC) in the treatment of recurrent depression.

    Get PDF
    Impaired ability to recall specific autobiographical memories is characteristic of depression, which when reversed, may have therapeutic benefits. This cluster-randomized controlled pilot trial investigated efficacy and aspects of acceptability, and feasibility of MEmory Specificity Training (MEST) relative to Psychoeducation and Supportive Counselling (PSC) for Major Depressive Disorder (N = 62). A key aim of this study was to determine a range of effect size estimates to inform a later phase trial. Assessments were completed at baseline, post-treatment and 3-month follow-up. The cognitive process outcome was memory specificity. The primary clinical outcome was symptoms on the Beck Depression Inventory-II at 3-month follow-up. The MEST group demonstrated greater improvement in memory specificity relative to PSC at post-intervention (d = 0.88) and follow-up (d = 0.74), relative to PSC. Both groups experienced a reduction in depressive symptoms at 3-month follow-up (d = 0.67). However, there was no support for a greater improvement in depressive symptoms at 3 months following MEST relative to PSC (d = -0.04). Although MEST generated changes on memory specificity and improved depressive symptoms, results provide no indication that MEST is superior to PSC in the resolution of self-reported depressive symptoms. Implications for later-phase definitive trials of MEST are discussed

    Validation of Polar Precision PrimeTM heart rate measurement at rest and during exercise

    No full text

    RR interval signal quality of a heart rate monitor and an ECG Holter at rest and during exercise.

    No full text
    This study was designed to examine the RR interval signal qualities of a Holter device and a heart rate chest belt monitor at rest and during exercise. Ten healthy individuals completed five low- to high-intensity activities while simultaneously using the medilog; ®; AR12plus? Holter monitor and the Polar H10 heart rate monitor. The RR interval signal quality was based on the quantification of the missing RR intervals and RR interval detection errors. Therefore, both measurement systems were compared against visual inspection of the raw electrocardiography signal. The missing and wrong R-wave peak detections were counted manually for both measurement systems. RR interval signal quality was defined as the relative number of correctly detected RR intervals. Overall, RR interval signal qualities of 94.6% and 99.6% were demonstrated for the medilog® AR12plus and the Polar H10. During the high-intensity activities, the RR interval signal quality of the medilog® AR12plus dropped to 89.8%, whereas the Polar H10 maintained a signal quality of 99.4%. The correlation between both systems was high (r=0.997, p>0.001). The excellent RR interval signal quality during low- to moderate-intensity activities in the medilog® AR12plus and during low- to high-intensity activities in the Polar H10 demonstrates both measurement systems' validity for the detection of RR intervals throughout a wide range of activities. A simple chest strap such as the Polar H10 might be recommended as the gold standard for RR interval assessments if intense activities with strong body movements are investigated
    corecore